UC2000-L2-U-V15/ UC2000-L2-I-V15
< Sensor head bidirectional and rotatable
< Function indicators visible from all directions
< Quick mounting bracket
< Selectable sound lobe width
< Programmable
General specifications
Sensing range 60 ... 2000 mm
Adjustment range 80 ... 2000 mm
Dead band 0 ... 60 mm
Standard target plate
100 mm x 100 mm
Transducer frequency
approx. 175 kHz
Nominal ratings
Response delay
minimum: 60 ms
factory setting: 330 ms
Time delay before availability ≤ 1600 ms
Input
Input type: 1 program input
Level (evaluation limit 1): 0 ... 1 V
Level (evaluation limit 2): 4 V ... UB
Input impedance > 12 kΩ
Pulse length 2 ... 10 s
Output
Output type: 1 analog output 0 ... 10 V
Resolution: evaluation range [mm]/4000, but ≥ 0.4 mm
Deviation of the characteristic curve : ≤ 0.2 % of full-scale value
Repeat accuracy : ≤ 0.1 % of full-scale value
Load impedance: ≥ 500 Ohm
Temperature influence :≤ 1.5 % of full-scale value